SITE OVERVIEW
Capacity – Supporting a total of 210 racks in 42U or 48U 600mm x 1,000mm up to dual 32A diverse power supplies. From ¼ rack options and above.
Configuration – 7 Data Halls – each data hall supporting 100m², up to 35 racks or 120kW in secure suites, cages or shared configurations.
Support – 24×7 on-site remote hands, monitoring and support available to all customers. On-site Cloud, Managed Services and Colocation.
Security – Steel perimeter fencing, HD CCTV cameras, secure and updated reception area. PAC access controlled into each suite.
Power – 1,500kVA incoming supply from Scottish Power to on-site substation and transformer. Power delivery is 2N to each rack in each suite.
Cooling – Blended Ambi-Cool, Fresh Air and DX redundant cooling solutions to 700kW.
UPS – 2N Blended Emerson and MGE Galaxy units with up to 60 minutes autonomy.
Standby Generation – 2 x CAT 900kVA Standby Rated + 2 x FG Wilson 220kVA Standby Rated units in N+1 configurations.
NEWBRIDGE SITE SPECIFICATIONS
Total Technical DC Sq Ft – 6,600
No of Data Halls – 7
Total Rack Capacity – 210
Building Floors – 2
Floor Void – 400mm
Tier Rating – Tier 3
Total Power Provision – 1.5MVA/1,200kW
Total Power Protection – N+1
Total UPS Provision – 1.68MVA/1,300kW
Total UPS Protection – 2N
Rack Provision – Dual 16Amp or 32Amp
Total Generator Provision – 2.24MVA/1,792kW
Total Generator Protection – N+N
Total Generator Fuel Storage – 15,000 Litres
Total Cooling Provision – 700KW
Total Cooling Protection – N+1
Cooling Type – Chilled Water with Free Cooling
CCTV – Total Cameras – 24 Cameras
CCTV – Retention Period – Minimum 90 Days
Access Control – Type – Swipe Entry/Exit External Doors Swipe & Pin
Access Control – Retention Period – Minimum 12 Months
Fire Protection Systems – Floor and Ceiling Sensors
Fire Suppressant Systems on-site – IG451 and FM200
NEWBRIDGE SITE COLOCATION PROPOSITIONS
Rack Capacity – 210
1U Server
1/4 Rack
1/2 Rack
Full Rack
Oversized Rack
Dual PDU
Cage
Suite
1Mb – 1Gb Transit
Site Backhaul
Carriers – 4
PCI-DSS SP 2.0
ISO 27001:2013
Managed Server
Colocation Backup
DC Connectivity On-Net Services – BT, Virgin Media, SSE, Gamma
POWER & GENERATORS
To eliminate risk from outage or power failure, the site uses diverse supplier feeds from multiple grid points ensuring there is no single point of failure. The site will provide 2N+1 redundant power systems and power feeds up to 10kW per racks to ensure continuous power.
FIRE DETECTION & SUPPRESSION
Ensuring our infrastructure and customer equipment operate safely is one of our greatest concerns. The facility is equipped with VESDA fire detection which continuously sample the air for smoke particles. In the event of an alert we have installed a FM200 suppression system.
DATACENTRE FACILITIES
Pulsant have built a number of client facilities into the site to ensure any time you spend on-site is comfortable. There is ample provision for client IT staff who may be required on-site, this includes parking, rest rooms, kitchen, build facilities, dedicated offices and meeting rooms.
COOLING & PERFORMANCE
Energy is vital to power and cool servers, we reduce energy consumption and costs by using ultra-efficient systems and advanced cold aisle and pod technology.
MULTI LEVEL SECURITY
Pulsant do everything possible to prevent unauthorised access to the site, buildings and data halls as well as to the rack housings themselves. We have systems in place to identify and react to threats so that your infrastructure is protected from theft, damage or interference. The site is a PCI DSS Level 1 compliant facility.
NETWORK & CONNECTIVITY
When creating the data campus we needed to ensure we had ultra-fast connectivity with low latency to London locations. We achieved this as the site houses diverse network connectivity via Dark Fibre to multiple London points of presence with 2ms of network latency.
Address & Contact
Our Address
Claylands Road EH28 8LF Edinburgh United Kingdom
GPS
55.927536, -3.4112405
Telephone
-
-
Web
-
Reviews
0.0
0
Leave a Review
Price
Location
Staff
Services
Food
Publishing ...
Your rating has been successfully sent
Please fill out all fields
Captcha check failed
Comments 0