SITE OVERVIEW
Capacity – Supporting a total of 250 racks in 42U or 48U 600mm x 800mm up to 4kW. Available in single server, ¼, ½, full rack, caged and suite environments.
Configuration – 1 Secure Data Hall – racks available in Amp, kW per annum and kWh models in singular rack to caged configurations. Ideally situated for primary or disaster recovery solutions from London, Slough, Swindon, Bristol or Reading.
Support – 24×7 on-site remote hands, monitoring and support available to all customers. With a wide range of high capacity network solutions from 1Mb to 10Gb.
Security – Steel perimeter fencing, secure 24×7 manned security entrance with CCTV cameras, PAC access controlled into each area of the site.
Power – 2MVA incoming supply from SSE to on-site substation. Power delivery is N to each rack in each suite.
Cooling – N+1 DX redundant cooling solutions to 700kW.
UPS – N+1 PowerWAVE with up to 30 minutes autonomy.
Standby Generation – 1 x FG Wilson 2MVA set.
MAIDENHEAD P1 SITE SPECIFICATIONS
Total Technical DC Sq Ft – 6,500
No of Data Halls – 1
Total Rack Capacity – 240
Building Floors – 1
Floor Void – 400mm
Tier Rating – Tier 2
Total Power Provision – 2MVA/1,600kW
Total Power Protection – N
Total UPS Provision – 1.2MVA/800kW
Total UPS Protection – N+1
Rack Provision -Single 16Amp
Total Generator Provision – 2MVA/1,600kW
Total Generator Protection – N
Total Generator Fuel Storage – 5,000 Litres
Total Cooling Provision – 700KW
Total Cooling Protection – N+1
Cooling Type – DX
CCTV – Total Cameras – 16 Cameras
CCTV – Retention Period – Minimum 90 Days
Access Control – Type – Swipe Entry/Exit
Access Control – Retention Period – Minimum 12 Months
Fire Protection Systems – Floor and Ceiling Sensors and VESDA system
Fire Suppressant Systems on-site – FM200
MAIDENHEAD P1 SITE COLOCATION PROPOSITIONS
Rack Capacity – 240
1U Server
1/4 Rack
1/2 Rack
Full Rack
Cage
1Mb – 1Gb Transit
Dark Fibre
Site Backhaul
Carriers – 9
PCI-DSS SP 2.0
ISO 27001:2013
Colocation Backup
DC Connectivity On-Net Services – BT, Telia, Virgin Media, Colt, Geo Networks, KCOM, Janet, Vodafone, TalkTalk
POWER & GENERATORS
To eliminate risk from outage or power failure, the site uses diverse supplier feeds from multiple grid points ensuring there is no single point of failure. The site will provide N+1 redundant power systems and power feeds up to 10kW per racks to ensure continuous power.
FIRE DETECTION & SUPPRESSION
Ensuring our infrastructure and customer equipment operate safely is one of our greatest concerns. The facility is equipped with VESDA fire detection which continuously sample the air for smoke particles. In the event of an alert we have installed a FM200 suppression system.
DATACENTRE FACILITIES
Pulsant have built a number of client facilities into the site to ensure any time you spend on-site is comfortable. There is ample provision for client IT staff who may be required on-site, this includes parking, rest rooms, kitchen, build facilities, dedicated offices and meeting rooms.
COOLING & PERFORMANCE
Energy is vital to power and cool servers, we reduce energy consumption and costs by using ultra-efficient systems and advanced cold aisle and pod technology.
MULTI LEVEL SECURITY
Pulsant do everything possible to prevent unauthorised access to the site, buildings and data halls as well as to the rack housings themselves. We have systems in place to identify and react to threats so that your infrastructure is protected from theft, damage or interference. The site is a PCI DSS Level 1 compliant facility.
NETWORK & CONNECTIVITY
When creating the data campus we needed to ensure we had ultra-fast connectivity with low latency to London locations. We achieved this as the site houses diverse network connectivity via Dark Fibre to multiple London points of presence with 2ms of network latency.
Address & Contact
Our Address
Priors Way SL6 2HP Maidenhead United Kingdom
GPS
51.5008802, -0.7093311
Telephone
-
-
Web
-
Reviews
0.0
0
Leave a Review
Price
Location
Staff
Services
Food
Publishing ...
Your rating has been successfully sent
Please fill out all fields
Captcha check failed
Comments 0